This study investigated the performance of an enhanced modified Ludzack Ettinger process-oxic settling anaerobic (MLE-OSA) system for treating real municipal wastewater at the Sari wastewater Treatment plant in Iran. The research combined the OSA process technique with the MLE system utilizing three reactor configurations: MLE, MLE-OSA4, and MLEOSA6. Each reactor incorporated Sludge Holding Tanks (SHT) at different retention times – 4-h and 6-h – to optimize nutrient removal.
Process Monitoring and Results
The process began with the overflow effluent from the primary settling tank of the plant. After a stabilization period of 45-60 days, regular monitoring of Dissolved Oxygen (DO), Oxidation-Reduction Potential (ORP), temperature, pH, Chemical Oxygen Demand (COD), Biochemical Oxygen Demand (BOD5), Total Suspended Solids (TSS), and nutrients was conducted. The study aimed to assess the impact of the modified process on effluent quality. The results indicated that the MLE-OSA4 and MLEOSA6 systems demonstrated improved performance compared to the standard MLE control. Specifically, the MLEOSA4 system showed reductions of 20.1%, 14.6%, 2.97%, 10%, 51.1%, 19.3%, and 20.7% for TSS, COD, BOD, phosphorus, nitrite, nitrate, and total nitrogen, respectively, in the effluent. The MLEOSA6 system achieved even greater reductions, with decreases of 34.2%, 16.1%, 14.6%, 16.7%, 69.6%, 31.3%, and 25.8% for the same parameters.